Business-critical storage failure?1-800-228-8800
ADRADR Data RecoveryRAID · Server · NAS · Virtualization Start Emergency Triage

TN-R6-003 — Latent Sector Errors Under Dual-Parity Stress

Author: ADR Data Recovery

Program: InteliCore Logic™

0. Purpose and Scope

This note explains why RAID 6 rebuilds expose latent sector errors more aggressively than RAID 5.

1. Rebuild Read Amplification

  • Reed–Solomon parity requires additional survivor reads.
  • Each stripe exercises all remaining members.
  • Cold data regions are fully scanned.

2. Latent Errors as Effective Drive Loss

  • One UNC consumes one parity symbol.
  • Second UNC at same stripe exceeds solvability.
  • Controller halts to avoid parity corruption.

3. Practical Outcome

RAID 6 rebuilds stall not because parity is weak, but because parity math is being protected.