Business-critical storage failure?1-800-228-8800
ADRADR Data RecoveryRAID · Server · NAS · Virtualization Start Emergency Triage

RAID 5 data recovery

RAID 5 data recovery after one or two drive failures.

Stop writes and preserve every member. ADR can identify the usable drive set, protect unstable sources, determine the array layout, and reconstruct the data without asking the failed controller to rebuild it again.

The server does not need to boot, the volume does not need to mount, and the RAID 5 does not need to be brought online before ADR can begin.

Members firstIdentify every source and replacement
Read-only accessProtect unstable drives before reconstruction
Layout verifiedOrder, offset, stripe, and parity checked
Output separatedRecovered data goes to other storage

Start with the symptom

What is the RAID 5 doing now?

The number of failed labels is only part of the story. What the controller changed, which members remain readable, and what happened during any rebuild determine the safest next step.

Two drives failed or went offline

The controller has exceeded RAID 5 fault tolerance, but a failed label does not prove both members are physically unreadable.

Review this condition →

One drive failed and the array is offline

RAID 5 should normally remain available after one member drops. An offline volume means another condition must be identified before rebuilding.

Review this condition →

The rebuild failed or stalled

Keep the original member and the partial rebuild target. Both may contribute to recovery.

Review this condition →

Another drive failed during the rebuild

Stop the rebuild and preserve the original member, replacement member, and every surviving source before the failure state changes again.

Review this condition →

The virtual disk disappeared

Do not recreate or initialize it. Preserve the member order and controller state before testing the layout.

Review this condition →

The configuration is foreign or missing

Controller metadata can be evaluated without importing, clearing, or replacing it on the original drives.

Review this condition →

SQL Server or a database is affected

Protect the RAID and database files as separate layers before attach, repair, or log rebuilding.

Review this condition →

The recovery path

ADR does not use the hardware rebuild as the recovery method.

The failed server and controller are evidence, not prerequisites. If the drives can be connected independently to a controlled recovery system, ADR can begin while replacement infrastructure is prepared.

  1. 1

    Record the state

    Capture the controller, server, RAID level, bay order, drive identities, errors, and actions already attempted.

  2. 2

    Protect the members

    Access sources read-only and image drives whose stability or coverage is uncertain.

  3. 3

    Reconstruct virtually

    Determine member order, data offset, stripe size, and parity rotation away from the failed controller.

  4. 4

    Recover and verify

    Validate files, databases, virtual machines, or other priority data and write the result to separate storage.

Historical client account

Two members were reported failed.

“We lost two drives out of three in a RAID 5. ADR recovered our data and kept the process professional from start to finish. I recommend ADR to anyone facing the same position.”Bryan Neely · January 2012 · Historical client account

We can get started now

Tell ADR what failed and what has already been tried.

Begin with the controller or NAS model, RAID level if known, drive count and capacities, current messages, rebuild history, and the business data needed first.