Business-critical storage failure?1-800-228-8800
ADRADR Data RecoveryRAID · Server · NAS · Virtualization Start Emergency Triage

Both RAID 60 Groups Are Degraded and No Array Is Found

When both lower RAID 6 groups are degraded and the RAID 60 virtual disk is gone, the controller cannot assemble the compound array from the member state it sees. Recovery begins by treating each lower group as its own reconstruction problem.

Preserve the current state.

Do not recreate the RAID 60, force either group online, or start parallel rebuilds. Preserve every original and replacement member from both groups.

What this condition means

Each lower group may have different failures, member histories, and readable coverage. One group cannot be assumed healthy simply because more of its drives respond.

Only after both lower groups are reconstructed can the stripe across them be tested for the expected capacity, filesystem, and data.

What to record

What not to do

How ADR evaluates it

ADR identifies and protects the members, then reconstructs each lower RAID 6 group independently using the best available sources.

The recovered groups are joined at the top layer and checked against the expected filesystem and priority data before output is accepted.

What happens next

The missing virtual disk does not have to be restored on the original controller. ADR can work from the complete member set and rebuild the two layers in a controlled recovery environment.